Why a thermal fluid system from baharan palayesh ?
Thermal fluid systems on ships are used to supply heat for various kinds of heat con- sumers like fuel oil tanks, separators and fuel heaters and to heat all types of cargo such as bitumen, oil products and chemi- cals. Also tank washing systems, steam generators and central heating systems are typical fields of application.
In thermal fluid systems, the produced heat is transferred to the ship’s heat consumers by means of a transfer fluid, usually a mineral oil. Pumps circulate the fluid through the closed system, passing
Advantages for shipyards
Fast and professional proposals
Complete engineered system solutions
More than 10 years of experience in thermal fluid technology
In-house production of core products
Simple system with a limited number of components to be installed
Delivery of all necessary system com- ponents
Compact heaters with a small foot- print
Small heating surface in the tanks
Extensive list of references
Advantages for shipowners
Heating systems using thermal flu- ids to transfer thermal energy are low maintenance, high perform- ance and environmentally friendly solutions.
The fluid remains in a liquid phase during the entire process, enabling high tem- peratures with the lowest possible pres- sures. The simplicity of our system and the non-corrosive nature of the oil makes this a very reliable and low maintenance solu- tion. Our system is easy to operate and due to the way we design the system, the thermal oil has a long lifetime
Capacity: 100000 - 3,000,000 kcal Thermal fluid design temp.: 250ºC -350ºC
Oil-fired thermal fluid heater
Vertical or horizontal execution
Constructed with a double coil of bare tubes
Three-pass flue gas configuration resulting in high efficiency
Removable top plate provides access for inspection and cleaning of the coils
Low thermal fluid pressure drop
Heavy insulation jacket
Burner: Monoblock pressure jet burner
Rotary cup burner
MODELS HPN |
100S |
200S |
350S |
600S |
800S |
1000S |
1200S |
1400S |
1600S |
Specifications |
|
|
|
|
|
|
|
|
|
Heat Output Million BTU/hr |
1 |
2 |
3.5 |
6 |
8 |
10 |
12 |
14 |
16 |
Million Kcal/hr |
.25 |
.5 |
.875 |
1.5 |
2 |
2.5 |
3 |
3.5 |
4 |
Flow Rate-Standard *1 GPM |
75 |
150 |
265 |
425 |
600 |
725 |
900 |
1050 |
1200 |
M3/min |
18 |
35 |
61 |
97 |
137 |
165 |
205 |
239 |
273 |
Flow Rate-Low Flow *2 GPM |
40 |
75 |
135 |
225 |
300 |
375 |
450 |
525 |
600 |
M3/min |
10 |
18 |
31 |
52 |
69 |
86 |
103 |
120 |
97 |
Circulating Pump Motor-STD HP |
7.5 |
15 |
20 |
30 |
40 |
50 |
60 |
75 |
100 |
kW |
5.6 |
11.2 |
14.9 |
22.5 |
29.8 |
37.3 |
45 |
56 |
74.5 |
Circulating Pump Motor-LF HP |
7.5 |
7.5 |
15 |
20 |
30 |
30 |
40 |
30 |
40 |
kW |
5.6 |
5.6 |
11.2 |
14.9 |
22.5 |
22.5 |
29.8 |
22.5 |
29.8 |
Blower Motor HP |
1/3 |
1 |
2 |
7.5 |
10 |
10 |
5 |
7.5 |
7.5 |
kW |
.25 |
.7 |
1.5 |
5.6 |
7.5 |
7.5 |
4.3 |
5.6 |
5.6 |
Light Oil (approx. fuel usage)*3 GPH |
8.8 |
17.5 |
30.6 |
52.5 |
70 |
87.5 |
104.9 |
122.4 |
139.9 |
LPH |
33.3 |
66.2 |
115.8 |
198.7 |
265 |
331.2 |
397 |
463.3 |
529.5 |
Natural Gas (approx. fuel usage)*3 FT3/hr |
1,334 |
2,667 |
4,667 |
8,000 |
10,667 |
13,334 |
16,000 |
18,667 |
21,334 |
M3/hr |
37.4 |
75 |
131 |
224 |
299 |
373.4 |
448 |
522.7 |
597.4 |